A Guide for Efficiency in Waste Heat Recovery Boilers
Manufacturing industries use efficient steam boilers for operational purposes that require heat. Although steam boilers generate sufficient steam and heat for process plants, it also wastes a significant amount of heat that could be used for other purposes. Therefore, industries have started investing in waste heat recovery boilers to use as much wasted heat as possible and promote sustainability. Using the waste heat recovery for preheating combustion air is commonly used in medium- to high-temperature furnaces. Using preheated air for the burners reduces the amount of fuel required to meet the process heat requirements.
As the name suggests, using a waste heat recovery boiler to recover part of the exhaust gas heat is an option for plants that require a source of steam or hot water. The waste heat recovery boiler is similar to steam boilers with the difference of heating through the exhaust gas stream from a process furnace rather than its burner. Waste heat recovery boilers are the ideal solution for plants that need additional steam capacity. However, the boiler generates steam only when the process is running.
Heat Losses in Process Industry:
Depending on the process type, waste heat is released at any temperature from cooling water to high-temperature waste gasses from an industrial furnace. Usually, high temperature leads to a high quality that is more cost-effective for heat recovery. In case of any waste heat recovery boiler, there must be some use for the recovered heat. With heat recovery of high temperature, a cascade system of waste heat recovery is practiced to ensure the optimal amount of heat, recovered at the highest potential.
In any waste heat recovery, it is essential to know the amount of heat recoverable. In a heat treatment furnace, the exhaust gasses exit the furnace at 900°C at the rate of 2100 m3/hour.
The total heat recoverable at 180oC final exhaust is calculated as,
Q = V × ρ × Cp × ∆T
Where,
Q = heat content in kCal
V = flowrate of the substance in m3 /hr
ρ = density of the flue gas in kg/m3
Cp = specific heat of the substance in kCal/kg °C
∆T = temperature difference in °C
How to Increase Efficiency in Waste Heat Recovery Boilers?
- Minimize exhaust gas temperatures:
Excessive exhaust gas temperatures are caused by poor heat transfer in the furnace. If the combustion gasses fail to transfer the maximum possible heat to the furnace and its contents, it exits the furnace at higher temperatures than necessary. Optimizing heat transfer within the furnace requires different methods, depending on the situation.
Overloading a furnace can also cause excessive stack temperatures. For the proper heat transfer rate, combustion gasses should remain in the heating chamber for the appropriate amount of time. Usually, an overloaded furnace runs colder than optimal unless the temperature is artificially high. It leads to the burners operating at higher than normal firing rates, increasing combustion gas volumes. The higher gas flow rates and shorter time in the furnace result in poor heat transfer, leading to a higher temperature for the flue gasses. Increased volumes of high-temperature flue gasses result in significantly increased heat losses. Due to this, high production goals are accomplished, but at the cost of excessive fuel consumption.
- Minimize exhaust gas volumes:
The two ways to lower waste gas flows are preventing overloading and optimizing heat transfer along with others. The ideal way is to control fuel-air ratios. Operating the furnace at the optimal fuel-air ratio for the process controls fuel consumption. It can be performed with the existing control equipment with little maintenance attention. A reduction in the exhaust volumes is the indirect result of efficiencies applied elsewhere.
- Use of oxygen-enriched combustion air:
Ambient air consists of approximately 21% oxygen with nitrogen and other inert gasses as balance. The total volume of exhaust gasses is reduced by increasing the oxygen content of combustion air by mixing in ambient air or by using 100% oxygen. Reducing exhaust gasses leads to substantial fuel savings. The amount of saved energy depends on the percentage of oxygen in combustion air and the flue gas temperature. High values of oxygen and flue gas temperature offer higher fuel savings.
Benefits of Waste Heat Recovery Boiler:
The benefits of waste heat recovery boilers are broadly classified into two categories:
Direct Benefits:
The recovery of waste heat directly impacts the efficiency of the operation process. It is proved by the reduction in utility consumption, utility costs, and process costs.
Indirect Benefits:
Pollution reduction: Various combustible wastes like carbon monoxide gas, carbon black off-gasses, oil sludge, acrylonitrile, plastic chemicals, etc., are burned in the incinerators, it release into the atmosphere, and serve the dual purpose of recovering heat and reducing pollution levels.
Reduction in equipment sizes: Waste heat recovery boiler reduces the fuel consumption, leading to a reduction in the produced flue gas. It leads to a reduction in the sizes of all flue gas handling equipment like fans, stacks, ducts, burners, etc.
Reduction in auxiliary energy consumption: Reduction in equipment sizes results in additional benefits with a reduction in auxiliary energy consumption like electricity for fans, pumps, etc.
Rakhoh Waste Heat Recovery Boilers:
Since its inception in 1983, Rakhoh has consistently strived for advancement and sustainability for the betterment and progressive future. Aiming that, Rakhoh manufactures highly efficient Waste Heat Recovery Boilers that are compact and customized in design. It processes gas turbine, and biogas gensets exhaust, enabling fully automated operation. Its construction is customized as a fire tube and water tube, depending on the clients’ requirements.
For more details, visit www.rakhoh.com
- Published in Boiler
A Guide to Combustion Tuning in Steam Boilers
When process plants operate steam boilers for generating steam, they ensure that the combustion process is performed with optimal fuel consumption and steam production. It is a fact that combustion is pivotal in generating steam, with operating personnel endeavoring for as proper and optimum combustion process as possible. The combustion process requires a precise amount of fuel, oxygen, and ignition for the desired results. The steam boiler should be tuned with the proper air/fuel mixture for attaining optimum efficiency. Excess amount of oxygen in steam boilers results in reducing the boiler efficiency. However, excess fuel in the steam boiler can lead to severe failure.
Combustion Process in Steam Boilers:
The combustion process in steam boilers includes three stages, i.e., pre-heating, actual ignition, and post-combustion. A steam boiler burner system consists of air shutters to control the amount of air mixed with natural gas for proper burning. When air intake is controlled properly, it makes an impact if the fuel is wasted or the energy efficiency is increased by enhanced boiler combustion optimization.
Combustion Optimization in Steam Boilers:
With the advancement in combustion optimization technologies and procedures, there has been a significant increase in the boiler efficiency. It is essential to note that steam boiler burners need tuning in a compatible manner with the steam boiler system and design. There are various types of steam boiler systems and designs available in the market, but boiler burners require adjustment to operate properly within their particular boiler system or design type. Steam boilers need balancing for the air-to-fuel ratio to optimize fuel consumption and to provide maximum heat output at all times. If furnace components like nozzles, pilot assemblies, gas valves, etc., are out of working order, it may lead to steam boiler performance problems.
Importance of Boiler Tuning:
Steam boiler combustion is an integral function, necessary for generating steam and heat. Therefore, a boiler requires to be inspected at least annually by a qualified boiler service technician or engineer. The regular tune-ups of the steam boiler ensure that the system will continue to operate safely and efficiently. During this process, it is crucial to pay close attention to the boiler firing rate that can be adjusted using regulator settings on the motorized gas valve. The boiler combustion is deemed optimal as long it can allow air into the burner flame. If the airflow gets blocked, it leads to blocking of proper combustion and heat generation. Regular boiler combustion tuning should be considered as the topmost priority for preventing any hazardous problems such as carbon monoxide poisoning and air pollution.
Problems in Steam Boiler Combustion Tuning:
When the boiler combustion tuning problems remain unresolved by technicians, it can lead to boiler system breakdowns. Forced air gas or oil furnaces are the most common boiler burners that require tuning. It needs tuning if the input coal is of an inappropriate size or the air intake of the boiler is too high for its design. If the steam boiler is releasing a lot of sparks, then the cause may be low boiler airflow. Low airflow is caused due to the oversized burners on the boiler with high excess air. A boiler technician will be able to determine whether or not the boiler furnace needs tuning so that it operates properly and provides maximum heat output.
For the steam boiler to operate properly and produce maximum heat from the fuel, its combustion requires it to be balanced and have an optimum output. Negligence in the tuning of a boiler’s burner will result in generating low heat output and an excessive amount of fumes. It would cause a significantly excessive expenditure by using more fuel than necessary.
Tips to Increase the Boiler Efficiency:
- Seasonal tune-up:
It is recommended to tune the burner during the spring and again in the fall because of the difference in the air temperature and density changes that take place during these seasons.
- Tune the boiler when it is hot:
A cold boiler tends to discard the actual operating O2 and CO readings.
- Parallel positioning systems:
Parallel positioning systems along with integrated flame management allow outdated technologies to be efficient as they can be.
- Periodically monitor flue gas composition:
Regular monitoring and tuning of the boilers are necessary to maintain excess air at optimal levels. Online monitoring of the flue gas oxygen level quickly detects the energy loss patterns that can offer early warning of control failures and data to help in the decision making.
- Utilizing a pre-mix technology:
The technology achieves an 85% fuel/air premix, making the adjustments easier. Premix technologies also allow the boiler to achieve and maintain a 3% oxygen output that improves turndown ratios. As a result, steam is generated more quickly with significant fuel savings.
Conclusion:
Since its inception in 1983, Rakhoh Boilers has been providing industrial steam boilers and thermal solutions of world-class quality in over 26 countries worldwide.
Learn more about our products and services by visiting www.rakhoh.com
- Published in Boiler
Direct Method and Indirect Method Testing of Efficiency in Boilers
Efficiency is an important factor in evaluating the performance of the boiler. The overall boiler efficiency depends on the efficiency of the various other components. The boiler efficiency is mainly determined by its combustion and thermal efficiency. It can be affected by some other losses as well.
Combustion Efficiency:
The combustion efficiency determines the burner’s ability to burn the fuel. The combustion efficiency is indicated by the amount of unburned fuel and oxygen level in the exhaust. Combustion efficiency depends on the fuel burned and is higher for liquid and gaseous fuels than solid fuels.
Thermal Efficiency:
Thermal efficiency indicates the effectiveness of the heat exchanger to transfer the heat energy in the boiler. Scaling and soot formation on boiler tubes negatively impact thermal efficiency.
Boiler Efficiency Testing:
Apart from combustion efficiency and thermal efficiency, other parameters affect the overall efficiency, such as blowdown losses, on-off losses, convection losses, radiation losses, etc. Boiler efficiency is calculated through two methods,
Direct Method: The direct method of testing boiler efficiency involves comparing the energy of the fluid (water and steam) with the fuel energy
Indirect Method: The indirect method of testing efficiency determines the difference between the losses and the energy input in the boiler
Direct Method of Testing Boiler Efficiency:
The direct method is also termed as input-output method as it only requires output (steam) and input (fuel) to assess the boiler efficiency and can be calculated by the following formula,
Boiler Efficiency = (Heat Output/Heat Input) x 100
Measurements Required for Direct Method Testing of Efficiency:
Heat Input:
Both heat input and heat output are imperative for calculating efficiency. Heat input measurement requires the calorific value of the fuel and its flow rate in terms of mass or volume, depending on the fuel.
Solid fuel: Measuring an accurate flow rate of coal or any other solid fuel is challenging. Measurement based on mass requires an apparatus set-up in the boiler house. The sample bags are sealed and sent to laboratories for testing.
Liquid fuel: Heavy fuel oil is viscous that causes it to vary with temperature. The meter installed in the combustion appliance provides approximate results, and it is advisable to use a calibrated meter for the particular fuel.
Gaseous fuel: A gas meter used requires the measured volume to be corrected for temperature and pressure.
Heat Output:
Various methods are used to measure heat output. Steam boilers use the installed steam meter to measure the flow rate. With small boilers, feed water can be measured by calibrating the feed tank. Heat addition used for conversion of feed water to inlet steam must be considered for heat output. Additionally, the heat loss during continuous blowdown should be calculated and included in the steam heat.
Advantages of Direct Method of Testing Boiler Efficiency:
- Quick evaluation of efficiency
- Needs few factors for calculation
- Requires less instruments for testing
Disadvantages of Direct Method of Testing Boiler Efficiency:
- Causes of low efficiency remain unspecified
- Does not calculate various losses at different stages
- Wet steam due to carryover may lead to incorrect evaporation ratio and efficiency
Indirect Method of Testing Boiler Efficiency:
The indirect method includes measuring all the losses that take place in the boiler. The efficiency is calculated by subtracting heat loss from 100. Unlike the direct method, slight measurement errors would not significantly change the efficiency rate in the indirect method. The various types of heat losses in boilers are losses due to hydrogen in fuel, dry fuel gas, moisture in fuel, carbon monoxide, air moisture, convection, surface radiation, unburned losses in fly ash and bottom ash, etc.
Boiler efficiency can be calculated by the indirect method of testing with the following formula,
100 – Losses occurred in the boiler
Measurements Required for Indirect Method of Testing Boiler Efficiency:
The parameters required to measure boiler efficiency through the indirect method are as follows,
- Flue gas analysis in terms of percentage of carbon dioxide, oxygen, and carbon monoxide in flue gas, and temperature of flue gas
- Flowmeter measurements for feed water, condensate water, fuel, steam, and combustion air
- Temperature measurements for fuel, makeup water, steam, flue gas, combustion air, feed water, and condensate return
- Pressure measurements for fuel, steam, draft, and combustion air (primary and secondary)
- Water conditions for Total Dissolved Solids (TDS), Blowdown rate, and pH
Advantages of Indirect Method of Testing Boiler Efficiency:
- Complete balance between mass and energy for individual stream
- Alternatives to improve boiler efficiency are identified
Disadvantages of Indirect Method of Testing Boiler Efficiency:
- Requires considerable time
- Needs lab settings for analysis
Factors that improve boiler efficiency:
- Regular maintenance of boilers
- Excess air control
- Quality of Fuel
- Boiler insulation
- Proper water treatment
- Optimal steam pressure and temperature
Rakhoh Boilers are one of the reputed steam boiler manufacturers and service providers in India and worldwide. With 38+ years of experience, we deliver world-class quality boilers and the best boiler services to our clients for enhancing efficiency and productivity. To learn more about our products and services, visit www.rakhoh.com
- Published in Boiler
An Introduction to Different Types of Fans in Thermal Plants
Combustion is pivotal for heating in steam boilers. Air is crucial for combustion and plays an important role in fuel burning and must be supplied with precision, in different ratios, depending on the type of fuel used. Steam boiler systems in Thermal Power plants use different types of centrifugal fans. It provides air for combustion, fuel to the burners, circulates the gasses for enhanced heat transfer, and releases exhaust gasses. Depending on the boiler size and airflow requirement, various types of fans are used with varying capabilities. Draught fans are essential in thermal power plants by providing tremendous support to the various process activities related to power generation.
Two types of fans used in a boiler power plant are– Draft Fans and Other Process Fans.
- Draft Fans:
Draft fans are important for thermal power plants as it maintains the flow of gasses through the steam boiler system. Draft fans are classified further as Forced Draft fans and Induced Draft Fans.
Forced Draft fans in the power plant are centrifugal fans, utilizing radial airflow blading. It provides the necessary air for fuel combustion by pushing air through the combustion air supply system to the furnace. Located at the inlet of the boiler to push high-pressure fresh air into the combustion chamber, it mixes with the fuel to produce positive pressure.
Compared to Induced Draft fans, Forced Draft fans are more efficient and easy to maintain with clean operating conditions. Backward curved and airfoil centrifugal fans are the most common centrifugal fans used as FD fans.
Induced Draft Fans exhausts all flue gasses from the boiler through the dust collector, passing it to the chimney and into the open atmosphere. Therefore, ID fans are located at the outlet of the steam boiler system. Induced Draft fan creates a negative pressure to discharge the gasses after combustion from the furnace.
As Induced Draft fans can capably handle hot flue gasses, it faces more corrosion and erosion issues. Radial fans and backward inclined blade centrifugal fans are the most common types of Induced Draft fans used in a boiler power plant.
Other Process Fans:
Other Process fans used in a boiler power plant are,
- Primary Air Fan
- Secondary Air Fan
- Flue Gas Recirculation Fan
- Primary Air Fan:
Primary air fans or PA fans are high-pressure fans that supply the air for transportation of coal in the boiler power plants directly from the pulverizer to the furnace. PA fans supply positive pressure upstream of the coal pulverizer.
In power plants, Primary Air fans provide air in conveying the pulverized coal to the furnace area. PA fans produce pressure upstream of the pulverizer for pushing the coal and air mixture through the pulverizer into the furnace.
The most common centrifugal fan used as a PA fan in a boiler power plant is Backward Curved Centrifugal Fan.
- Secondary Air Fan:
The secondary fans or SA fans play a vital role in power plants. The secondary fan helps with the complete combustion of the fuel in the furnace. SA fans increase the airflow as required, to improve efficiency and avoid fuel wastage. Coal-fired thermal plants account for the highest share of electricity generation compared to other methods like hydroelectric, wind, gas, or solar-based plants. Furthermore, SA fans can run continuously. Considering the transportation expenses and high costs of coal mining, it is not ideal to do inefficient burning of the coal in the furnace. Due to all the mentioned factors, secondary fans play a key role in maintaining the efficiency of the thermal power plant.
- Flue Gas Recirculation Fan:
Flue gas recirculation fan reduces the flue gas pollution content in the exhaust gasses from thermal combustion processes. Flue gas recirculation fans are used in a power plant boiler for controlling steam temperature and furnace heat absorption.
Flue gas recirculation fans extract gas from the economizer outlet and the inlet of the pre-heater. It later discharges the gas either to the bottom of the furnace to control the steam temperature or to different locations in the furnace.
Backward curved centrifugal fans are the most common type of gas recirculation fans used in a boiler power plant.
Role of Primary Air Fan and Secondary Air Fan in Thermal Plants:
Air supplied in thermal plants boilers for combustion reacts with the fuel as per its stoichiometric ratio. However, some percentage of air provided for combustion remains unreacted.
It usually occurs due to the fuel quantity fed at once and variation in the fuel particles size. Therefore, a certain amount of extra air requires to be provided to compensate for the air that went unreacted.
Conclusion:
Fans of various types and ratings are used as process fans in power plants. Draught fans are typically heavy-duty centrifugal fans that are an essential and irreplaceable component of a thermal power plant.
Rakhoh Boilers is a leading boiler manufacturer in Pune since 1983 with a successful record of installing 3000+ boilers in over 26 countries worldwide. We provide superior quality steam boilers, waste heat recovery systems, thermic fluid heaters, and boiler accessories.
To learn more about our products and services, visit www.rakhoh.com
- Published in Boiler
A Guide to PLC and SCADA Automation in Steam Boilers
Steam Boilers are one of the most important equipment in any power plant and process industry that require constant monitoring and inspection at frequent intervals. In a steam boiler, various sections are controlled at the same time with primary sections, such as the boiler drum, a boiling section producing high-temperature water for steam generation. Excessive water level leads to improper steam generation. Steam & Drum Level is critical and difficult to measure and maintain to automate the system and reduce human errors. Precise control of the water level in the drum is an important factor that is performed by developing a PLC and SCADA system. It helps to reduce the manual operation and provide enhanced control and monitoring of the plant and process operations through a SCADA system, a centralized system for supervising the process by preparing the required data respective to process changes.
Programmable Logic Controller (PLC):
Programmable Logic Controller (PLC) is a digital computer for automation that can re-program the logic as per the users’ requirements in industries. PLC is also used for the internal storage of instruction for the function implementation such as logic, sequencing, timing, counting, and arithmetic to control through digital or analog input/ output modules.
Working of Programmable Logic Controller (PLC):
At the start of each operational cycle, the CPU brings in all the field input signals from the input signals from the module to store them into internal memory as a process of the input signal. This internal memory of the CPU is known as the process input image (PII).
The user program is available in the CPU program memory. The CPU takes the status of input from PII and processes it in the user program, and its result is stored in the internal memory of the CPU. This internal memory is called process output image. At the end of the program run, the CPU transfers the signal states in the process image output to the output module and resultantly, to the field control.
- Input-Output in PLC
- Input Layout:
- Feed Pump
- RTD Transmitter
- Level Switch
- Pressure Transmitter
- Output Layout:
- Solenoid Valve for the water inlet
- Solenoid Valve for Steam Outlet
- Heater
Supervisory Control and Data Acquisition (SCADA):
As the name suggests, SCADA stands for Supervisory Control and Data Acquisition that helps with the supervisory level as it is not a complete control system. SCADA is used for monitoring and controlling plants or equipment. The control may be automatic or managed by operator commands. The data acquisition is completed by the PLC’s scanning the field inputs connected to the PLC that is usually at a fast rate. The central host scans the PTU’s at a slow rate and the data is processed to detect alarm conditions. If an alarm is present, it is displayed on special alarm lists.
PLC and SCADA in Industries:
PLC and SCADA are used to develop and implement boiler automation. Various sensors measure the temperature, pressure, and water level. The parameters are assessed through SCADA, and the operation is controlled by using PLC. The entire arrangement shuts down if the temperature and pressure reach a predetermined value and the automatic check valve opens to discharge the steam and pressure. An emergency alert is activated, and automatic check valves are opened to avoid any hazardous failure. Boiler control is a crucial part of any process plant.
The steam boiler in a process plant or power generation project is controlled through a variety of methods. The method to be used is determined by several objectives such as rising profit, increased efficiency, superior quality, and other factors that are dependent on the industry. Boiler automation has become vital for meeting the primary goal of providing easy operation to these facilities and the needs of the industries. The changes that are consistently taking place in the industrial sector are partially the result of boiler automation. The automation process, which is gradually assuming its position in all process plants throughout the world, has been given priority. It has prepared itself to examine the critical components of the entire process operation, along with their implementation and any difficulties that may arise.
Conclusion:
Rakhoh Boilers are renowned for their efficient and reliable steam boilers, waste heat recovery boilers, thermic fluid heaters, and boiler accessories since their inception in 1983. We also provide excellent boiler services like energy audit, steam trap assessment, boiler automation, annual boiler maintenance, fuel conversion, etc., to enhance the efficiency and productivity of steam boilers.
Learn more about our products and services at www.rakhoh.com
- Published in Boiler